How to quickly deal with the low-temperature chiller compression molding machine card?




It is widely used in some industries such as industry, and the compressor jam of low-temperature chiller is a serious problem, which needs to be dealt with in time to avoid further damage to the equipment. However, when some enterprises are operating low-temperature chillers, the system condenser has been left for a long time, causing the condenser shell and tube to rust, and the rust residue enters the system compressor and freezes. So, how to deal with low-temperature chiller compressor card machine?

The following are some quick treatment methods for low temperature chiller compressor card:

1. Stop the power supply of the machine: Once the compressor is found to be stuck, it should be stopped immediately to avoid further damage. Close the exhaust valve and angle valve, turn off the power supply, and make sure that the power supply has been completely cut off.

2.Check the cause: Check the cause of the machine jam, which may be caused by overload, overheating, poor lubrication or other mechanical failures. Troubleshooting may require professional technicians.

3. Clean up the fault: If you can handle it yourself, you can try to clean up the substance that is stuck in the compressor. First, make sure the device is down and powered off. Using the correct tools, carefully remove any debris that has become lodged in the compressor. Make sure to pay attention to your own safety to avoid additional damage.

4. Check the lubrication system: Check the lubrication system to ensure that the lubricating oil and cooling water of the compressor are normal. Make sure that the lubricating oil level is within the normal range, and replace or add it in time. Check the cooling water circulation system to make sure the water flow is clear and there is no blockage or pump failure.

5.After exhausting the fluorine, remove the suction pipe and exhaust valve bolts, and then remove the power line of the mechanical motor and the loading solenoid valve. Then remove the bottom corner bolts of the compressor and lift it with a hoist; wrap all the removed power cord connectors and pipe connectors with tape, seal the suction pipe with a blind plate, turn on the refrigeration pump cycle, and vacuum.

6.Seek professional help: If the above methods cannot solve the problem, or further repair work is required, you should contact professional technicians or repair service providers, report the stuck situation to them, and ask them for further inspection and repair. They have the experience and expertise to diagnose and fix this serious problem.

The above is the introduction of Jiusheng technicians on "how to deal with low-temperature chiller compressor jamming". The technicians remind: when the low-temperature chiller stops operating for a long time, the company must drain the water in the unit, which can greatly avoid the frequency of low-temperature chiller failures. It is important to play it safe when dealing with a stuck compressor. Stop and remove power from the equipment, and seek professional assistance if needed. Do not attempt to repair unfamiliar equipment parts as this could cause further damage or injury.
Navigation